TEKTRONIX TDS 3014B CALIBRATION and TEKTRONIX TDS 3014B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS 3014B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS 3014B (TDS3014B)   Description / Specification:    
TEKTRONIX TDS 3014B 4 Ch 100 MHz Digital Phosphor Oscilloscope

100 MHz, Digital Phosphor Oscilloscope, Four Channel. Sample Rate on Each Channel: 1.25 GS/s. Maximum record length: 10 K points on all models. Vertical resolution: 9 Bits on all models. Vertical sensitivity (/div): 1 mV – 10 V on all models. Vertical accuracy: ±2% on all models. Max input voltage (1 M-Ohm): 150 VRMS CAT I on all models (300 V CAT II with standard 10X probe). Position range: ± 5 div on all models. BW limit: 20 MHz. Input coupling: AC, DC, GND. Input impedance selections: 1 M-Ohm in parallel with 13 pF or 50 ohm. Time base Range: 4 ns – 10 s/div. Time base Accuracy: 20 ppm. Trigger System; Main Trigger Modes: Auto (supports Roll Mode for 40 ms/div and slower), Normal. B Trigger: Trigger after time or events. Trigger After Time Range: 13.2 ns to 50 s. Trigger After Events Range: 1 to 9,999,999 events. External Trigger Input: >1 M- Ohm in parallel with 17 pF; Max input voltage is 150 VRMS. Trigger Types; Edge: Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: DC, noise reject, HF reject, LF reject. Video: Trigger on all lines, odd, even or all fields. With TDS3VID or TDS3SDI, trigger on individual lines and on analog HDTV formats (1080i, 1080p, 720p, 480p). Display (VGA) Color active matrix LCD



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS 3014B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your TEKTRONIX TDS 3014B CALIBRATION and/or TEKTRONIX TDS 3014B 4 Ch 100 MHz Digital Phosphor Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: